Two weeks to Thursday 26 November 2026 · checks completed 07:49 · 36 systems, 4,445 checks
The last seven days in one line
14 added, 4 cleared
Critical findings are up 10 on the week, at 60 across 13 systems. 1 cluster fails a host loss.
60
Critical findings
▲ 10 on the week
0
Critical incidents
0 older than 90 days
87
Behind on KEV patches
82 ESXi, 5 vCenter
36 of 36
Systems read in full
every system read
7
Accepted risks to review
1 past their date, 6 due in 30 days

1Health by platform and site

Average score per cell, with the change over the last seven run days on the right and the number of systems on the left when there is more than one. An empty cell means that platform is not at that site.

VK6HX1PEV1HPCMGMTNGCLABAvamar100Avi Load Balancer94-3Cisco Intersight86-5Cisco UCS8995-5Data Domain90100100Dell ECS9697-3Dell iDRAC servers99x3Dell PowerMax99+5Dell PowerScale97Dell PowerStore100100Dell Unity98-2NSX99+196OpenManage100+10PowerProtect DM9091Proxmox9996Pure FlashArray99-1x298Pure FlashBlade96Veeam M365100VMware95-189-291-191-191vRNI100
  • 90 or more
  • 80 to 89
  • under 80

2What moved

Critical findings added and cleared day by day, the systems whose score moved most, the checks behind most of the critical findings, and who holds the open incidents.

Critical findings: added and cleared

Net change per system, last 14 run days, after accepted risks
addedcleared13 Nov321316 Nov123119 Nov122422 Nov1115126 Nov
14 added and 4 cleared in the last seven days.

Biggest movers

Score change over the last seven run days, points
UCS Manager - HLD-5Intersight - HX1-4.5Dell ECS - Halden-2.9Avi Controller - WMR-2.8Unity - NGC-2.3vCenter - HLD Prod-1.5NSX-T Manager - WMR+1.1PowerMax - WMR+4.6OpenManage Enterprise - WMR+10
11 systems moved by a point or more.

Most common failing checks

Critical findings by check, today
VM Snapshot Age30Snapshot Delta Size13Blade2Fault Summary2VLAN Consistency1VDS Health1Sustained Load Summary1Security Policies1Password Expiry1
The top two checks are 72% of everything critical.

Open incidents by team and age

1 open, 0 critical
Storage team11
  • Under 8 days
  • 8 to 30
  • 31 to 89
  • 90 or more
0 critical incidents are 90 days old or more.

3Resilience and patching

Every cluster with its largest host lost, and where the estate stands on the builds that close vulnerabilities being exploited now.

Memory in use after losing the largest host

Highest 9 of 9 clusters; amber over 80%, red over 90%
WMR-MGMT-CL0191%PEV-PROD-CL0281%NGC-PROD-CL0278%NGC-PROD-CL0166%WMR-PROD-CL0165%PEV-PROD-CL0163%WMR-PROD-CL0261%HLD-PROD-CL0246%HLD-PROD-CL0141%fits under 80%
Would not fit: WMR-MGMT-CL01 (memory).

On the safe build, by product

Against the CISA known-exploited list and the approved patch baseline
VMware ESXi, 4182VMware vCenter, 55
  • On a safe build
  • Behind
VMware ESXi: CVE-2025-22226, CVE-2025-22225, CVE-2025-22224, CVE-2024-37085 and 2 more. VMware vCenter: CVE-2026-123890, CVE-2026-59310, CVE-2024-37079, CVE-2024-38813 and 9 more.

4Capacity and what falls due

Every array against the 85% order line, last night's backups by system, and the dates coming up.

Storage runway, all arrays

Used today, and months to the 85% order line at present growth
PowerScale - WMR76%2 monthsPowerMax - WMR66%4 monthsPowerStore - HLD63%4 monthsUnity - NGC62%4 monthsPowerStore - PEV62%4 monthsFlashArray - WMR-B61%4 monthsDell ECS - Westmere61%7 monthsDell ECS - Halden61%7 monthsFlashArray - WMR-A60%5 monthsFlashArray - HLD60%5 monthsFlashBlade - WMR58%3 months85% order line
Every array reported capacity on the latest run.

Backups by system, last day

Share of each system's jobs; the number after the name is its job count
PPDM - WMR, 5854PPDM - HLD, 3331Avamar - WMR, 4343Veeam - PEV, 88
  • Succeeded
  • Finished with warnings
  • Failed
  • Other
5 failed jobs across the systems shown. Backup results are listed, not scored.

Due in the next 90 days

Capacity orders, certificates in use, support contracts and accepted risks to review. Anything already past its date sits at today.
DEC 2026JAN 2027FEB 2027Capacity ordersPowerScale - WMR: order nowFlashBlade - WMR: order nowPowerStore - HLD: order byPowerStore - PEV: order byUnity - NGC: order byPowerMax - WMR: order byCertificatesAvi Controller - WMR, 15 Dec4 certificates, from 15 JanvCenter - HLD Prod, Avi Controller - WMR, 4 FebSupport contractsnothing dueAccepted risks4 reviews due, from 26 Nov2 reviews due, from 10 Dec3 reviews due, from 25 Dec
  • Within 14 days
  • Within 30 days, or needs an order
  • Later

5Is the monitoring itself healthy

Collections that failed, ran slow or did not read a system in full, and how long collection takes.

Collection by system, last 14 days

The last run of each day; only systems with a miss or a slow run
vCenter - HLD ProdUnity - NGCProxmox - PEV13 Novtoday
  • Read in full
  • Slow (three times its usual)
  • Failed
  • Not read in full
  • No run
33 of 36 systems were read in full on every day they ran.

Collection time, minutes

Every system's last run of the day added up, last 14 days
010821518313 Novtoday
Slowest today: PPDM - HLD (571 s), Aria Operations for Networks (529 s), PowerStore - HLD (512 s). Hourly hardware pass: last at 26 Nov 14:40, 11 systems in 54 seconds; 0 collections did not finish across the last 3 passes.

6The lists

What is behind the charts: findings that turned critical on the latest run, and every open incident.

Turned critical on the latest run (0)

Nothing turned critical on the latest run.

Open incidents (1)

SeveritySystem and incidentTeamVMsTenantsOpen
WarningFlashArray - WMR-A · VK6 / Westmere
not reporting - Replication Connection: Target: 9, Status: degraded, Type: vSAN
Storage team17821 d

7About this brief

Added and cleared is the change in each system's critical findings from one run day to the next, with today's accepted risks applied to every day; a system that gained three and lost three on the same day shows as no change. A run that pulled under 30% of a system's usual checks is treated as missing data and skipped. Movers compare the latest score with the one seven run days earlier. Clusters are tested with their largest host lost against the capacity planner's limits. Collection shows the last run of each system on each day: failed is a run that ended in error, not read in full is a run with under 30% of the usual checks, slow is over three times that system's usual time (and over three minutes).