Window: 2026-10-27 to 2026-11-26 (30 days) — fleet average active memory 20.9%
8 open finding(s) (8 Critical) — see Open Findings section
3 VM(s) currently hold at least one snapshot.
All reporting VMs have current, running VMware Tools.
2 VM(s) have no backup policy tag assigned in source data.
Highest memory pressure: QUIL-FS06 (peak 31% active of 16 GB)
2Fleet composition
Operating system
Win Srv 2019
4
Win Srv 2022
4
Ubuntu Linux
2
Microsoft Windows 11
1
Red Hat Enterprise Linux 9
1
SUSE Linux Enterprise 15
1
Win Srv 2016
1
vCenter
?
14
Top hosts (by VM count)
hld-esx-c201
2
hld-esx-c104
1
hld-esx-c203
1
ngc-esx-c102
1
ngc-esx-c104
1
ngc-esx-c201
1
ngc-esx-c202
1
ngc-esx-c203
1
3Open findings & hygiene
VM
Check
Severity
Detail
QUIL-VDI17
VM Snapshot Age
Critical
'VeeamSnapshot' is 38 days old (108.1 GB) - created by t.marlow
QUIL-VDI17
Snapshot Delta Size
Critical
'VeeamSnapshot' delta 108.1GB = 63% of provisioned 172.2GB - consolidation will be disruptive
QUIL-VDI17
Snapshot Delta Size
Critical
'Pre-upgrade' delta 132.6GB = 77% of provisioned 172.2GB - consolidation will be disruptive
QUIL-FS14
VM Snapshot Age
Critical
'Pre-upgrade' is 25 days old (118.1 GB) - created by ops-automation
QUIL-FS14
VM Snapshot Age
Critical
'Pre-upgrade' is 67 days old (259 GB) - created by ops-automation
QUIL-APP04
VM Snapshot Age
Critical
'Pre-upgrade' is 29 days old (77.3 GB) - created by t.marlow
QUIL-APP04
VM Snapshot Age
Critical
'Change CHG0041223' is 14 days old (73 GB) - created by ops-automation
QUIL-LNX17
VM Legacy NIC
Critical
iSCSI
Snapshot hygiene
3 VM(s) currently hold at least one snapshot.
VMware Tools currency
All reporting VMs have current, running VMware Tools.
4Backup protection
This shows policy assignment, not confirmed job success. Each VM's assigned backup policy name is read directly from source-system tagging. A live cross-reference against actual PPDM protection status was attempted for this fleet and did not succeed (appliance unreachable or not resolvable) — treat this section as "is a policy assigned", not "did last night's backup succeed".
Assignment
2 VM(s) have no backup policy tag assigned in source data.
QUIL-VDI17
QUIL-SAP26
Policies in use (12 VMs tagged)
Gold-Daily
12
5Storage footprint
VMs per datastore
HLD-C2-PSTORE-DS04
3
NGC-C2-UNITY-DS03
2
WMR-C1-PURE-A-DS01
1
PEV-C1-PSTORE-DS01
1
NGC-C2-UNITY-DS02
1
NGC-C1-UNITY-DS02
1
PEV-C2-PSTORE-DS01
1
NGC-C2-UNITY-DS01
1
HLD-C1-PURE-DS02
1
NGC-C1-UNITY-DS01
1
WMR-C1-PURE-A-DS02
1
WMR-C2-PURE-B-DS02
1
PEV-C1-PSTORE-DS04
1
Datastores in use
13 distinct datastore(s) host this fleet, 3667 GB used in total across all VMs (per-datastore GB isn't attributable from the source data when a VM spans multiple datastores, so this total is fleet-wide, not split per datastore).
6ServiceNow reference
Not yet integrated. Morning-Rounds has no live ServiceNow API connection, so ticket data cannot be pulled into this report. No ServiceNow CI reference (SNOWID tag) was found on this fleet's VMs.
7Worth a closer look
QUIL-FS06
Peak active memory 31% of 16 GB allocated · avg 31% · 4 vCPU, peak 764 MHz · Win Srv 2019 on pev-esx-c105
8Per-VM performance (14 VMs with usage history)
Reading the memory columns: vCenter reports two memory numbers. "Consumed" includes cached/reserved pages VMware is holding but not necessarily using — it reads misleadingly high on almost every VM. "Active" (the colour-coded figure shown here) is the real working set. This report ranks and colour-codes by Active, not Consumed. CPU is shown as raw MHz, not a percentage, since an accurate per-core baseline for these hosts wasn't confirmed.